Issue 30910  —   P209: Previous modal Form no longer Maximized though APS uses Maximize Forms

Status:   Solved in 10.2.01

Solution available in patch(es):      MX07    G101

Description:

 Summary:
 After closing a Modal form the previous modal Form is no longer
 Maximized though APS uses Maximize Forms.
 This occurs since patch P209.

 Environment:
 - Uniface: 9.3.02 + P209 and later versions.
 - Operating System: OS independent
 - Database: DBMS independent

 Symptoms:
 After closing a Modal form the previous modal Form is no longer Maximized
 though APS uses Maximize Forms.

 The following two examples illustrate the issue:

   ** Example 1 **

   1. APS TEST uses Maximize Forms
   2. Modal form TESTSTART is activated.
   3. Via a button or other trigger like the <PRINT> trigger,
      the modal form TESTA is activated

   Note that until now all modal forms appear correctly maximized.

   4. Close form TESTA.

   Note that form TESTSTART is no longer maximized.

   ** Example 2 **

   1. APS TEST uses Maximize Forms
   2. Modal form TESTSTART is activated.
   3. Via a button or other trigger like the <PRINT> trigger,
      the modal form TESTA is activated
   4. Via the <PRINT> trigger modal form TESTB is activated

   Note that until now all modal forms appear correctly
   maximized.

   5. Close form TESTB

   Note that form TESTA is no longer Maximized.

Workaround:

 Set Windows property Maximize to all the modal forms.

Notes:

 This problem is solved.